Composites & Glass Fiber
Silanes for Long Glass Thermoplastics and Continuous Tapes
Silanes for long glass thermoplastics help match a reinforcement surface to its polymer and compatibilizer package. The right interphase supports stress transfer while the complete sizing system allows roving unwinding, bundle opening and polymer penetration in LFT, GMT or continuous-fiber production.
LANDUSIL supplies amino, ureido and glycidoxy silanes for glass-interface development. We work from the material you manufacture—long-fiber pellets, inline compounds, mats, tapes or organosheets—so selection follows your actual impregnation and forming sequence.

What Interface Chemistry Does for Long Glass Reinforcement
- Matches glass to the polymer formulation: choose the organic group around the matrix and its available reaction or interaction sites.
- Supports reinforcement load transfer: develop adhesion within a compatible glass–polymer interphase.
- Targets moisture-conditioned behavior: compare the interface under the conditioning and aging relevant to the part.
- Fits upstream sizing development: coordinate the silane with film formers and lubricants used to protect and handle the roving.
- Connects impregnation and forming: carry the interface comparison from feedstock manufacture into the final component.
Typical Uses
Thermoplastic route: Long-fiber thermoplastic pellets
Main process focus
Roving opening, melt impregnation, cooling and pellet consistency
Thermoplastic route: Direct long-fiber processing
Main process focus
Inline feeding, thermal history, distribution and retained length
Thermoplastic route: Glass-mat thermoplastics
Main process focus
Mat binder, heating, transfer and compression-forming consolidation
Thermoplastic route: Continuous tapes and organosheets
Main process focus
Bundle penetration, ply architecture and sheet consolidation
Thermoplastic route: Secondary forming and overmolding
Main process focus
Reheating, local joining conditions and the sheet-to-overmold interface
Recommended LANDUSIL Products
LANDUSIL LEGRA 1010-L offers a primary amino treatment route. The grades below provide different amine, glycidoxy or ureido functionality for a matrix-specific interface package.
| Product | Chemistry | CAS | Why choose it |
|---|---|---|---|
| LEGRA 1010-L | 3-Aminopropyltriethoxysilane | 919-30-2 | Primary amino triethoxy route for glass treatment matched to the polymer and compatibilizer. |
| LEGRA 1021-L | N-(2-Aminoethyl)-3-aminopropyltrimethoxysilane | 1760-24-3 | Primary and secondary amine functionality for comparing the long-fiber interphase package. |
| LEGRA 2011-L | 3-Glycidoxypropyltrimethoxysilane | 2530-83-8 | Glycidoxy-functional route where polyester end groups and processing conditions support the interaction. |
| LEGRA 7011-L | 3-Ureidopropyltrimethoxysilane | 23843-64-3 | Ureido-functional treatment option for a defined thermoplastic and existing glass size. |
How to Select Silanes for Long Glass Thermoplastics
Match the thermoplastic chemistry
For polyamides, choose amino or ureido chemistry with the actual polymer grade and glass size. Identify drying requirements and the specimen conditioning used for comparison. These inputs connect production moisture control with the mechanical state required for testing.
For thermoplastic polyesters, glycidoxy silane offers a route when the end groups, size and available melt history support the proposed interaction. For polypropylene, report the reactive compatibilizer chemistry and its addition point. Select the glass treatment and compatibilizer as a combined package.
Build the treatment into the reinforcement route
Coordinate original sizing with the reinforcement supplier, including film former, lubricant, treatment amount and thermal compatibility. An additional treatment needs a defined deposition and drying sequence for the size already present on the glass.
Neat triethoxy silanes release ethanol during hydrolysis; methoxy grades release methanol. Waterborne hydrolysates can enter an offline surface-treatment and drying route. Record their supplied content and carrier when defining the material that reaches the melt process.
Preserve the relevant reinforcement structure
For LFT pellets, follow roving wet-out through cutting and later molding. For D-LFT, record where fiber, polymer and additives enter the inline process. For GMT, identify the mat structure and binder before selecting the treatment.
Continuous tapes and organosheets require impregnation, stacking and consolidation suited to their ply architecture. During later forming, track alignment, textile shear, interply movement and wrinkling. These observations connect an interface ingredient with the component you intend to produce.
Application and Evaluation Guidelines
Use a reference size and polymer formulation, keeping glass content, architecture and molding conditions comparable. Track unwinding, fuzz, impregnation, voids and resin distribution. Measure retained fiber length after molding for finite-length routes; record ply direction and local defects for continuous reinforcement.
Set heating around the specific polymer's softening or melting behavior and grade-specific processing guidance. For reheated sheets, record transfer time and through-thickness temperature. Follow forming and cooling with thickness, orientation and consolidation checks.
Use mechanical, environmental and joint tests appropriate to the component, including failure examination. Glass-to-matrix adhesion does not establish sheet-to-overmold joining strength; test that interface under its own local thermal and pressure history. Pellet length does not establish retained molded length. Carbon reinforcement, in-situ polymerization, high-temperature matrices and mixed feedstocks need a chemistry and processing assessment for their actual route. Compare any proposed melt addition on composition, moisture, volatility and mixing conditions.

Frequently Asked Questions
Which silane is used for LFT glass reinforcement?
Amino, ureido or glycidoxy chemistry may fit different matrices. Begin with the polymer, existing size and compatibilizer, then compare roving impregnation and the properties of molded specimens.
What is the difference between LFT and D-LFT processing?
An LFT pellet route impregnates rovings and produces a feedstock for later molding. D-LFT combines inline melt compounding with the downstream forming operation, so the fiber's thermal and mechanical history differs.
How should glass treatment be chosen for polypropylene organosheets?
Identify the PP and reactive compatibilizer package, glass size and textile architecture. Choose the interface treatment with those materials, then evaluate impregnation, consolidation, forming and the required component properties.
What should be tested when an organosheet is overmolded?
Test the sheet's reinforcement performance and the polymer joining region. Include the relevant joint load, local forming history and failure location so each interface receives a useful assessment.

Samples and Technical Support
LANDUSIL provides samples, TDS, SDS and long-fiber interface selection support. Please include:
- Polymer grade, reactive compatibilizer and glass size
- Pellet, mat, tape or organosheet construction
- Impregnation, heating, transfer and forming equipment
- Fiber content, conditioning and target component tests
- Estimated volume, packaging preference and destination country