Electronics & Electrical
Silicone Gel Formulation for Electronics
Sensitive electronic structures need a protective material that follows movement while keeping stress on the component under control. A silicone gel formulation for electronics uses a lightly crosslinked network to combine compliant coverage with material retention around wires, sensors and populated boards.
LANDUSIL supplies vinyl-functional polymers, Si–H components and silicone resins for gel development. Formulators combine these ingredients with a matched catalyst and cure-control package, then adjust the network around the filling geometry and mechanical response of the assembly.

What a Silicone Gel Formulation for Electronics Does
- Provides compliant coverage. A flexible network accommodates movement around fragile parts and contacting surfaces.
- Fills complex spaces. Polymer selection and formulation rheology help liquid reach gaps around components before cure.
- Supports network adjustment. Vinyl content, hydride distribution and resin contribution give you variables for balancing softness with retention.
- Supports insulating gel development. The cured construction can be developed around the electrical demands of the module.
- Allows focused interface development. Contact-material screening helps establish consistent cure around the actual board and package surfaces.
Typical Uses
End use: Sensor encapsulation
What matters most
Membrane response, wire protection and mechanical load on sensitive structures
End use: Local PCB potting
What matters most
Controlled placement, wetting and air escape around closely spaced components
End use: Whole-board gel coverage
What matters most
Flow retention, filling depth and access for later repair
End use: Power module insulation
What matters most
Voids, field geometry, humidity and behavior under the intended voltage waveform
End use: Junction-box gel development
What matters most
Diode, wiring and housing compatibility with the required mechanical retention
Recommended LANDUSIL Products
These ingredients address the polymer, crosslinking and resin portions of a formulation. LANDUSIL DUVERA 5020-L supplies a vinyl-terminated base polymer.
| Product | Chemistry | CAS | Why choose it |
|---|---|---|---|
| DUVERA 5020-L | Vinyl-terminated polydimethylsiloxane | 68083-19-2 | Base polymer for a vinyl/Si–H network |
| DUVERA 4010-L | Polymethylhydrosiloxane | 63148-57-2 | Si–H component with its own reactive-site distribution |
| DUVERA 4020-L | Methylhydrosiloxane-dimethylsiloxane copolymer | 68037-59-2 | Copolymer route for adjusting the hydride contribution |
| NOVERA 3010-L | Vinyl MQ silicone resin | See SDS | Reactive resin phase for studying reinforcement, tack and network response |
| NOVERA 5010-L | Vinyl-functional silicone resin | See SDS | Additional resin approach selected by actual structure and reactive content |
How to Select the Gel Ingredients
Start with component sensitivity
Describe the structure that the gel will surround, including membranes, wire bonds and narrow clearances. Set a mechanical response target that relates to the component's function. For a mechanically retaining encapsulant, use the development approach in Elastomeric Electronic Potting.
Balance all reactive sites
Use actual vinyl and Si–H equivalents to calculate the formulation. Include the vinyl supplied by a reactive resin. Terminal vinyl polymers and pendant-functional copolymers place sites differently along the chains, so the distribution of those sites helps determine the resulting network.
Choose the resin contribution
NOVERA 3010-L is a vinyl MQ resin. NOVERA 5010-L provides a vinyl-functional resin whose architecture and carrier guide its own use. Compare their effects on mixing, cured response and phase compatibility while keeping the intended gel compliance in view.
Match filling and working time
Review the flow paths through your assembly and the route available for displaced air. Select a processing window that accommodates mixing, air removal, dispensing and filling. Include the cavity orientation and the time the liquid must remain in place before the network develops.
Application and Evaluation Guidelines
Establish a clean formulation reference, then bring in representative fillers, treated surfaces, plastics, soldering residues and neighboring adhesives. Sulfur-, nitrogen- and tin-containing contact materials can affect platinum cure; compare bulk cure with the interface next to each relevant material.
Measure cure progression, viscoelastic response, mobile fraction and retention. Lower crosslinker loading alone does not establish a useful soft gel. Check the component's response after encapsulation and conditioning so the mechanical assessment reflects the real geometry.
Include volatile release, extractables, migration and void development in your plan. The designed addition reaction still calls for evaluation of the complete mixture and any residual species. Record the cure and conditioning history for every comparison.
For power modules, define voltage waveform, switching behavior, frequency, temperature and humidity. Evaluate partial discharge or breakdown as appropriate to the construction. Ingredient identity cannot supply an assembly voltage rating, low-stress result or electronic purity specification.

Frequently Asked Questions
Which polymer is used to make an addition-cure silicone gel?
A vinyl-functional polysiloxane such as vinyl-terminated PDMS supplies the polymer portion. A matched Si–H component and catalyst form the network. Reactive resins may be included to adjust its response.
How do I adjust silicone gel softness?
Adjust polymer architecture, reactive equivalents, hydride distribution and resin contribution together. Compare the cured gel's response, mobile material and retention to find a network that suits your component.
Why does a silicone gel cure differently against a PCB?
Surface treatments, soldering residues, adjacent adhesives or handling contamination can change local cure. Use a clean reference and contact specimens from the intended assembly to locate the effect.
What should be measured for a power module gel?
Measure mechanical response, cure, voids and electrical behavior in representative module geometry. Add the relevant humidity, thermal cycling and applied waveform to the evaluation.

Samples and Technical Support
LANDUSIL provides samples, TDS, SDS and selection support for your silicone gel trials. Include:
- Component sensitivity, substrates and adjacent materials
- Cavity geometry, filling depth and dispensing method
- Polymer, fillers, catalyst system and cure-temperature constraints
- Gel response, electrical tests and conditioning requirements
- Estimated quantity, packaging preference and destination country