LANDUSIL LEGRA 5041-L is isobutyltrimethoxysilane, CAS 18395-30-7, a branched alkyl silane for hydrophobic mineral formulations and treated-filler development. The isobutyl group supplies nonpolar surface character, and three methoxy groups provide the hydrolyzable end of the molecule.

Formulators can use this combination to build a defined mineral treatment or introduce an isobutyl unit through controlled silane condensation. The methoxy route releases methanol, so solution preparation, drying and residual alcohol belong in the process design.

CAS number
18395-30-7
Molecular formula
C7H18O3Si
Molecular weight
178.3 g/mol
LANDUSIL LEGRA 5041-L sample bottle with LANDUSIL product card

Product Identity

ItemInformation
ProductLANDUSIL LEGRA 5041-L
Chemical nameIsobutyltrimethoxysilane
CAS number18395-30-7
Molecular formulaC7H18O3Si
Molecular weight178.30 g/mol
EC number242-272-5
Structure(CH3)2CHCH2Si(OCH3)3
Hydrolysis by-productMethanol
Product familyAlkyl Silanes

Specifications

PropertyValueTest method
AppearanceColorless clear liquidVisual
Purity (GC)min. 98.0 %Gas chromatography
Refractive index, nD201.3935 – 1.3985Refractometry

Typical Properties

PropertyTypical value
Density, 20 °Capprox. 0.930 g/cm³
Flash point, closed cupapprox. 11 °C
Boiling pointapprox. 154 °C

Typical values are provided for reference only and are not to be construed as specifications. Please refer to the current Technical Data Sheet (TDS) and Certificate of Analysis (CoA) for the supplied grade.

Technical Data Sheet

LANDUSIL LEGRA 5041-L

Specification limits, typical properties, guidelines for use, handling, storage and packaging in one document.

Document
TDS-LEGRA-5041-L-EN
Revision
1.0, November 2026
Format
PDF, 2 pages, 100 KB
Language
English

Key Features of Isobutyltrimethoxysilane

  • Branched alkyl substituent: provides an isobutyl surface group for adjusting wetting on suitable inorganic surfaces.
  • Three methoxy groups: support hydrolysis and siloxane formation under controlled conditions.
  • Mineral formulation flexibility: useful for developing treatments on defined concrete, masonry and stone substrates.
  • Filler surface-energy control: offers a nonpolar treatment direction for suitable silica and other accessible mineral surfaces.
  • Reactive concentrate ingredient: provides a monomer route for alkyl-silane blends and controlled oligomer development.

Applications

  • Textured gray concrete surface with streaks

    Concrete surface formulations

    LEGRA 5041-L supplies branched alkyl functionality for a formulated hydrophobic mineral treatment. For concrete protection, connect carrier and reaction conditions with uptake, treatment distribution and the required appearance of the cured surface.

  • Rain droplets on a grey textured surface

    Masonry and natural stone

    Use the silane in a treatment designed around a particular brick or stone and its accessible pore surfaces. Masonry and natural stone protection requires the formulation to balance water response, color and vapor transport.

  • Pile of white powder on round stone mortar

    Quartz and silica treatment

    The hydrolyzable silane end provides a route to modifying hydroxyl-bearing silica surfaces, while the isobutyl group changes the organic character of the treatment. Quartz and fused silica treatment connects that surface process with wetting and behavior in the receiving resin.

  • Laboratory beakers and flasks

    Water-repellent concentrate manufacture

    LEGRA 5041-L can serve as an ingredient in a compatible alkyl-silane concentrate or controlled reaction route. In silane water-repellent concentrate manufacture, establish carrier compatibility, water management and the intended application form together.

How to Use

For a building-surface formulation, establish the carrier, activation route and application method on representative cured specimens. Prepare clean substrates with a defined moisture condition, record uptake and assess the final treatment distribution. Compare water absorption, vapor transmission, color and wet/dry aging with an untreated control. Confirm performance for each stone or concrete surface used in your product range.

For silica or another mineral powder, define the accessible surface and treatment level before selecting the mixing route. Track hydrolysis, retained material, residual methanol and drying. Check moisture uptake, dispersion and viscosity in the intended binder. Isobutyl functionality adjusts surface energy; a resin-specific covalent coupling task may require an amino, epoxy or polymerizable silane.

For a concentrate or hybrid precursor, monitor residual methoxy groups, condensation, viscosity and gel development. Three hydrolyzable groups can introduce branching, so design the network around the whole precursor mix. Establish storage and working-solution stability through measurements on the resulting formulation.

Extend the evaluation to the actual end use. Cable fillers require compound electrical, mechanical and fire testing as applicable; glass treatments require optics and adhesion; metal surfaces require their own adhesion and corrosion program. Take operating limits such as boiling point and flash point from the current SDS for the supplied grade.

Guidelines for use

Mineral application
Dilute in a compatible formulation and apply to a clean, prepared surface. Match treatment concentration and curing to porosity and moisture; test appearance and water uptake after ageing.
Filler pretreatment
Distribute uniformly over an agitated hydroxylated powder. Control hydrolysis and drying, then check residual volatiles, agglomeration and binder compatibility.
Co-condensation
Add to a defined mixed-precursor system with controlled water addition, temperature and mixing. Follow pH, methanol release, viscosity and work-solution stability before coating or further reaction.

These levels are starting points. Determine the optimum level and method in trials under your own production conditions.

Packaging and Storage

  • Packaging: 25 kg plastic drum, 200 kg steel drum, 1,000 kg IBC. Other pack sizes on request.
  • Storage: Store in original, tightly closed containers in a cool, dry, well-ventilated area away from moisture, sunlight and ignition sources. Use opened containers promptly. Shelf life is 6 months from shipment in the original unopened container.
  • Handling and safety: Highly flammable liquid and vapor. Exclude ignition sources, ground transfer equipment and use effective exhaust ventilation. Vapors may cause drowsiness or dizziness. Avoid inhalation, skin and eye contact; use suitable chemical-resistant gloves and splash goggles. Moisture causes hydrolysis and toxic methanol release. Keep bulk liquid dry and control vapors during mixing, application and drying. Read the Safety Data Sheet before use.
Blue steel chemical drums in storage

Frequently Asked Questions

What is isobutyltrimethoxysilane used for?

It is a reactive ingredient for developing hydrophobic mineral treatments, modified fillers and silane concentrates. The isobutyl group changes surface energy while the methoxy groups provide hydrolysis and condensation chemistry.

What is the difference between isobutyl methoxy and ethoxy silanes?

LEGRA 5041-L carries methoxy groups and releases methanol. LEGRA 5040-L carries ethoxy groups and releases ethanol. Compare hydrolysis, drying and formulation stability in your process.

Can isobutyltrimethoxysilane treat quartz used in epoxy?

It provides a surface-energy modification route for suitable quartz. Assess treated-powder wetting and complete epoxy behavior, and select an epoxy- or amino-functional silane when the task requires a resin-reactive group.

LANDUSIL technical specialist in a lab coat holding a product sample bottle

Samples, TDS and Technical Support

LANDUSIL provides samples, current TDS and SDS, and selection support. Please share:

  • Mineral substrate or filler and receiving formulation
  • Carrier, treatment sequence and drying method
  • Target water response, processing and conditioned tests
  • Estimated quantity, packaging preference and destination country